BKPYN - CHROMABASE CLEAR, 7585S

Product Identification

Product ID:CHROMABASE CLEAR, 7585S
MSDS Date:01/01/1987
FSC:8010
NIIN:00N015241
MSDS Number: BKPYN

Responsible Party
E. I. DU PONT DE NEMOURS & CO INC
1007 MARKET STREET
WILMINGTON, DE 19898
US

Emergency Phone: 800-441-3637

Info Phone: 800-441-7515

Cage: 18897

Contractor
E.I. DUPONT DE NEMOURS & CO
WILMINGTON, DE 19898 US

Telephone: 800-441-7515;800-441-9442

Cage: 18873

Ingredients

ACETIC ACID, 2-METHOXY-1-METHYLETHYL ESTER (PGME ACETATE).

CAS: 108-65-6

RTECS: AI8925000

Fraction By Weight: 16%


XYLENES (O-,M-,P- ISOMERS) (SARA III)

CAS: 1330-20-7

RTECS: ZE2100000

Fraction By Weight: 22%

OSHA PEL 100 PPM/150 STEL

ACGIH TLV: 100 PPM/150STEL;9192

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


0.7 @ 20C.

CAS: 88230-35-7

OSHA PEL 50 PPM (MFR)

ACGIH TLV: 50 PPM (MFR)


ALIPHATIC POLYISOCYANATE.

CAS: 3779-63-3


1,6-DIISOCYANATOHEXANE (HEXAMETHYLENE DIISOCYANATE)

CAS: 822-06-0

RTECS: MO1740000

ACGIH TLV: 0.005 PPM; 9192

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


DECONTAMINATE SOLN OVER SPILL & ALLOW TO SIT 10

RTECS: 9999999ZZ


20% SURFACTANT (TERGITOL TMN 10) AND 80% WATER; OR

RTECS: 9999999ZZ


RPTD

RTECS: 9999999ZZ


OVEREXP MAY CAUSE ASTHMA-LIKE RXNS W/SHORTNESS OF

RTECS: 9999999ZZ


MAY BE DELAYED FOR SEVERAL HRS AFTER EXPOS. 1,6

RTECS: 9999999ZZ


RESP AND/OR LUNG IRRIT W/COUGH, DFCLT BRTHG, OR

RTECS: 9999999ZZ


W/SHORTNESS OF BREATH, WHEEZING, COUGH OR PERM LUNG

RTECS: 9999999ZZ


AFTER EXPOS. PRLNG SKIN CNTCT MAY CAUSE CHEM BURNS.

RTECS: 9999999ZZ

Fraction By Weight: NO

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:GENL EFTS: INGEST: GI DISTRESS. INHAL:
MAY CAUSE NOSE & THROAT IRRIT. RPTD/PRLNG OVEREXP TO SOLV MAY LEAD
TO PERM BRAIN & NERV SYS DMG. EYE WATERING, HDCH, NAUS, DIZZ & LOSS
OF COORD ARE SIGNS THAT SO LV LEVELS ARE TOO HIGH. EXPOS TO
ISOCYANATES MAY CAUSE ASTHMA-LIKE RXNS W/SHORTNESS OF BREATH, (SEE
EFTS OF OVEREXP)
Explanation of Carcinogenicity:NONE SPECIFIED BY MANUFACTURER.
Effects of Overexposure:HLTH HAZ: WHEEZING, COUGH OR LUNG SENSIT. EFTS
MAY BE DELAYED FOR SEVERAL HRS AFTER EXPOS. INDIVIDUALS WITH
LUNG/BRTHG PROBLEMS OR PRIOR RXN TO ISOCYANATES MUST NOT BE EXPOS
TO VAPS/SPRAY MIST OF PROD . EYE: MAY CAUSE IRRIT/BURNING. SKIN:
RPTD/PRLNG LIQ CNTCT MAY CAUSE IRRIT W/DISCOMFORT & DERMATITIS.
(SEE SUPP DATA)
Medical Cond Aggravated by Exposure:POLYISOCYANATE & 1,6 HEXAMETHYLENE
DIISOCYANATE: LUNG DISEASE, ASTHMA OR BREATHING DIFFICULTIES.

First Aid

First Aid:INGEST: IN THE UNLIKELY EVENT OF INGESTION, CALL MD
IMMEDIATELY AND HAVE NAMES OF INGREDIENTS AVAILABLE. INHAL: IF
AFFECTED BY INHALATION OF VAPOR OR SPRAY MIST, REMOVE TO FRESH AIR.
IF BREATHING DIFF ICULTY PERSISTS, OR OCCURS LATER, CONSULT MD.
EYE: IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR AT LEAST 15
MINUTES. CALL MD. SKIN: WASH WITH SOAP AND WATER. IF IRRITATION
OCCURS, CONTACT MD.

Fire Fighting

Flash Point Method:CC
Flash Point:20.0F,-6.7C
Lower Limits:1%
Upper Limits:13.1%
Extinguishing Media:WATER SPRAY, FOAM, CO*2, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . WATER FOG NOZZLES MAY BE USED TO COOL CLOSED
CONTAINERS TO PREVENT PRESSURE BUILD UP.
Unusual Fire/Explosion Hazard:WHEN HEATED ABOVE THE FLASH POINT, EMITS
FLAMM VAPORS WHICH, WHEN MIXED W/AIR, CAN BURN/BE EXPLO. FINE
MISTS/SPRAYS MAY BE FLAMM AT TEMPS BELOW THE FLASH POINT.

Accidental Release

Spill Release Procedures:DO NOT BREATHE VAPS. DO NOT GET IN EYES/ON
SKIN. WEAR A POS PRESS SUPPLIED AIR VAP/PARTICULATE RESP
(NIOSH/MSHA TC-19C), CHEM WORK GOGGLES, GLOVES & PROT CLTHG. REMOVE
SOURCES OF IGNITION. ABSORB W/IN ERT MATL. VENT AREA. POUR LIQ (SEE
INGRED 06)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:OBSERVE LABEL PREC. KEEP AWAY FROM
HEAT, SPARKS AND FLAME. CLOSE CONTAINER AFTER EACH USE. GROUND
CONTAINERS WHEN POURING. DO NOT STORE ABOVE 120F.
Other Precautions:DO NOT BREATHE VAPORS OR MIST. INDIVIDUALS WITH A
HISTORY OF LUNG OR BREATHING PROBLEMS OR PRIOR REACTION TO
ISOCYANATE SHOULD NOT USE OR BE EXPOSED TO THIS PRODUCT.

Exposure Controls

Respiratory Protection:WEAR POS PRESS SUPPLIED AIR RESP (NIOSH/MSHA
TC-19C) WHILE MIXING ACTIVATOR W/ANY PAINT/CLEAR ENAMEL, DURING
APPLICATN & UNTIL ALL VAPS/SPRAY MISTS EXHSTD. DO NOT PERMIT ANYONE
W/O PROT IN PAINT AREA. FOLLOW RESP MFR'S DIRECTIONS FOR USE.
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME AND PATTERN TO
KEEP CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:COVERALLS.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING OR SMOKING.
Supplemental Safety and Health
% VOLAT: 58.6-72.2 (VOL), 51.69-67.14 (WT). EFTS OF OVEREXP: SPECIAL
EFTS: PGME ACETATE: MAY CAUSE MOD EYE BURNING. RECURRENT OVEREXP
MAY RSLT IN LIVER & KIDNEY INJURY. XYLENE: HIGH CONC HAVE CAUSED E
MBRYOTOXIC EFTS IN LAB ANIMALS. RECURRENT OVEREXP MAY RSLT IN LIVER
& KIDNEY INJURY. CAN BE ABSORBED (SEE INGRED 08)

Chemical Properties

HCC:F3
Boiling Pt:B.P. Text:169F,76C
Vapor Pres:SEE INGRED
Vapor Density:> AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:MISCIBLE
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:SUPDAT

Stability

Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO, CO*2, SMOKE, OXIDES OF HEAVY
METALS REPORTED IN THE INGREDIENTS SECTION.

Disposal

Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. INCINERATE ABSORBED MATERIAL IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REQUIREMENTS. DO NOT INCINERATE IN CLOSED
CONTAINERS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.